How much carbon monoxide are you in when in any motor vehicle?

Did you know that many people do not measure the air they breathe?

After prevention there is no greater awareness than measurement.
Awareness leads to quick thinking. Measurement leads to quick action.

Are you in the know?

Do I know enough about carbon monoxide and carbon monoxide poisoning to justify never knowing how much is in the air I breathe every day, everywhere I go?”

There are some people who want to be notified of the presence of carbon monoxide at levels or concentrations as soon as the gas is present, at concentrations well below those that can instigate poor health symptoms but not be high enough levels to sound the CO alarm they own.

There are some people who do not want to push a button on their CO alarm to see what low, aggravating levels of the poison might be in their home, or anywhere.


The most recommended CO Alarm in U.S. is a high level alarm

Standard for Single and Multiple Station Carbon Monoxide Alarms
UL 2034
1.3 Carbon monoxide alarms covered by this standard are not intended to alarm when exposed to long-term, low-level carbon monoxide exposures or slightly higher short-term transient carbon monoxide exposures, possibly caused by air pollution and/or properly installed/maintained fuel-fired appliances and fireplaces…

Bob Dwyer
Carbon Monoxide Safety Association

COSA provides Carbon Monoxide safety education and training.

World Wide Reports - Pollution and Health Effects 
Carbon Monoxide News Links –
More news links below (International Spelling; no edits)

Multiple People Exposed To Carbon Monoxide, Hospitalized In Westchester
Rye Daily Voice
Multiple people are being transported to area hospitals after being exposed to carbon monoxide at an apartment complex in Westchester. - Police and fire officials received the call for a possible CO exposure around 8:30 a.m., Friday, April 19, at 56 Coyle Place in Yonkers, said Yonkers Police Lt. Jared Singer. (Updates Pending)

Greenpoint Gas Leak Causes Evacuation of Five Buildings
Greenpoint Post
On Tuesday, firefighters responded to a call concerning a gas leak near 77 Freeman St. around 1:15 p.m. after the building’s air monitors detected high levels of carbon monoxide. Once on the scene, residents from five Freeman Street buildings were evacuated as a precaution, an FDNY spokesperson said. - Five residential buildings were evacuated earlier this week in Greenpoint following a significant gas leak reportedly emanating from a manhole. (More)

Update, Video Report
Health authorities investigate after kids' blood test high for carbon monoxide on Oregon coast
KPTV.com (Video Report)
Health authorities investigate after kids' blood test high for carbon monoxide on Oregon coast. (Video Report)

Airdrie Fire Launches Annual Home Safety Campaign
DiscoverAirdrie.com
There's likely nothing worse than having an Airdrie firefighter knock on your door in the middle of the night to tell you your house is on fire. - There's also nothing better than having the same firefighter knock on your door in the middle of the day to tell you he's there to make sure you and your family know what to do in the event of a fire. - That's going to happen in some Airdrie communities over the course of the next month as the Airdrie Fire Department conducts its annual Home Safety Campaign. (More)

Hear how this Md. family had a close call after carbon monoxide leaked into their home
WJLA
When firefighters arrived, they confirmed dangerous carbon monoxide fumes had been leaking from the basement furnace. - Everyone in the house had gotten out just in time. - The smell came from insulation inside the furnace that was burning. - Banks wanted to know why no alarm went off and no alert was sent from the security company. - The next day, Banks said a Vivint inspector came to the house to see what went wrong. - He told her it appeared no carbon monoxide detector had been installed from the beginning. (More)

HUD moves to require carbon monoxide detectors in public housing after deaths
NBCNews.com
The Department of Housing and Urban Development is drafting the first federal rule requiring carbon monoxide detectors in public housing, after an NBC News investigation revealed the lack of protections for millions of low-income residents. - At least 13 people have died from the hazardous gas in federally subsidized housing since 2003, NBC News found. - The new requirement will go through the federal rulemaking process, which means it could be months, at a minimum, before it's implemented. (More)

Please Note: "Place a carbon monoxide alarm with a digital display on a seat in the motor vehicle when you are out driving in emergency snow conditions (or always for that specific). Harmful levels of carbon monoxide (CO) can penetrate inside a motor vehicle just due to prevailing winds and exhaust not moving away from the vehicle but under it. If you want to learn more about carbon monoxide, begin measuring it with a personal CO monitor everywhere you go." Bob Dwyer, CSME Carbon Monoxide Safety 
  
Scroll Down For More of Today's CO & Air Quality News Links 

Please, stop diagnostic errors; start testing for carboxyhemoglobin
--------
Video - Propane (LPG) tanks of any size can violently compound a structure fire – KEEP THEM OUTSIDE
BLEVE (Boiling Liquid Expanding Vapor Explosion) Demonstration - How it Happens Training Video--------

Carbon Monoxide Intoxication 
Journal of Neurology and Neuroscience
Carbon monoxide (CO) intoxication is one of the main causes of poisoning in industrialized countries and it often leads to diagnostic errors…

Carbon monoxide intoxication. 
nih.gov
However individuals with ischemic heart disease may experience chest pain and decreased exercise duration at COHb levels between 1% and 9%. COHb levels between 30% and 70% lead to loss of consciousness and eventually death…


Carbon Monoxide Safety Tips
National Fire Protection Association
… If the CO alarm sounds, immediately move to a fresh air location outdoors or by an open window or door. Make sure everyone inside the home is accounted for. Call for help from a fresh air location and stay there until emergency personnel….

NOTE: Listed U.L. 2034 & CSA 6.19 Carbon Monoxide Alarms
VISUAL DISPLAY:
Must not display under 30PPM in normal operation
AT 70, 150 & 400 PPM display must be accurate within plus or minus 30 Percent

SENSITIVITY TESTING: Resist alarming first times shown, must by second shown time
70PPM [PLUS OR MINUS 5PPM ... [BETWEEN 60 _ 240 MINUTES]
150PPM [PLUS OR MINUS 5PPM] ... [10 - 50 MINUTES]
400PPM [PLUS OR MINUS 10PPM ... [4 - 15 MINUTES]

“CITIZENS WILL CONTINUE TO DIE & BECOME SERIOUSLY ILL DAILY!”

George Kerr (1933-2017)

More news links below –

We have all been CO poisoned, some more than others
We have all inhaled carbon monoxide. We are a world of fire users.

What is in the air you are breathing right now?

What will you be doing today; walking into poison?
Who will be responsible for the air you breathe?
You may be the only person who can prevent your own poisoning.
We are all vulnerable to carbon monoxide exposure and poisoning.
Everyone has been poisoned by CO and will be poisoned again. The degree of the poisoning depends upon allowing yourself to be in a situation where someone else controls the air you breathe and the mechanisms for alarming notification.

Please read the alarm information on the package and in the instructions that come with the carbon monoxide alarm. Know that if it is a U.L. 2034 Listed product (or CSA 6.19 Listed), it is a high level alarm that has been tested to alarm no sooner than 70 PPM at the lowest (the alarm must resist for one hour when above this level) and when over 400 PPM before 15 minutes at the highest concentration, after resisting alarming for 4 minutes when over this level.

Know when your fire department and emergency responders begin wearing their breathing apparatus and what their civilian evacuation levels are for carbon monoxide; it may be as soon as the gas is present in your presence. Pregnant women, infants & children, people with heart & respiratory struggles, those suffering depression or chronic headaches and all people of vulnerable health should be alerted as soon as the gas begins to concentrate, around 10 PPM (parts per million) or lower.

You most likely need a low level carbon monoxide detector to sound off when carbon monoxide hazards are just beginning, not after you’ve been exposed to levels that make you have headaches, flu-like symptoms, increased tiredness, heart stresses or worse.

Do not take risks with carbon monoxide. Take responsibility for the air you breathe and the combustion systems you are responsible for. If you don’t do it for yourself, do it for others, unless you think $45.00, high level protection is good enough.

Help prevent injuries and deaths; don’t guess about carbon monoxide. Measure carbon monoxide for safety and knowledge. The more you test the more you learn. GET BUSY

Measurement is continuing education at its best. Bob Dwyer, CSME Carbon Monoxide Safety
"Love Song To The Earth" - Official Lyric Video

CO, Air Quality & Pollution News Links

Chasing Ghosts That Cause Illnesses
About 50 report illness after choral performance at Malcom X Elementary
Daily Californian
Later in the day, another student, student teacher and teacher reported similar symptoms. Preliminary tests for methane, carbon monoxide, hydrogen sulfide and volatile organic compounds by BFD and an environmental consultant did not identify any hazardous substances in the auditorium that could have caused the symptoms. (More)

Inmates return to Nowata County Jail nearly two months after carbon monoxide leak
KOKH FOX25
NOWATA COUNTY, Okla. (KTUL) - Nowata County Sheriff Mirta Hallett says five inmates have been moved back into the jail after they closed due to a carbon monoxide leak. - The fire department and county commissioners did a walk-through of the jail on Monday. After scanning the jail and sheriff's office, the fire chief's carbon monoxide detector came up clear. (More)

Martinsburg cement plant to pay $1.5M fine for air pollution
Herald-Mail Media
“This settlement demonstrates that EPA will hold accountable companies that fail to comply with operating permits that set forth requirements for protecting public health and the environment,” EPA Regional Administrator Cosmo Servidio said in a news release. “Communities have a right to be protected from hazardous air pollutants, and EPA continues to ensure those protections.” (More)
------
Sit and rest a while; miss the children, prevent repeating this tragedy.
Corfu carbon monoxide deaths: Memorial unveiled in Horbury 
BBC News - A memorial bench to two young children who died from carbon monoxide poisoning while on holiday in Corfu has been unveiled in West Yorkshire…

To all parents everywhere; grief's pain alerts others

Out of tragedy comes the light of love
Chester County Press
Inside, Carly and Daulton had passed away from carbon monoxide poisoning. The gas tank was empty and the ignition was still on. Fumes from the exhaust had been drawn into the car through the air vents… “One of the best things for me is to talk to parents who have also lost a child,” Donna said.
VideoNex
In this informative and succinct video, learn how to identify and appropriately execute the use of a CO2 Fire Extinguisher…


CDC Carbon Monoxide Poisoning 
New Movie Release 2015
Carbon Monoxide Poisoning. Public domain video from CDC. Carbon monoxide (sometimes referred to as CO) is a colorless, odorless gas produced ...
A well put together video is found with the next link, but remember: U.L. 2034 Listed CO Alarms are high level alarms. Use them for protection against acute levels, but be aware you can still experience symptoms of the poisoning even though the devices are in place.

DailyMotion
About Carbon Monoxide and Carbon Monoxide Poisoning

JEMS.com - ...site has been designed with this in mind – to create a visual, interactive, educational resource which can hopefully end incidents of carbon monoxide poisoning and save lives… For more information, please visit - www.thesilentkiller.co.uk


Who is responsible for the air you breathe?
Take control inside your homes. 
-Link to: → CO alarm standards – 
The lowest U.L. 2034 & CSA 6.19 carbon monoxide alarm test point is:
- 70 PPM to 149 PPM –resist one hour, must alarm before 4 hours

Please read the alarm information on the package and in the instructions. Know when your fire department and emergency responders begin wearing their breathing apparatus and what their civilian evacuation levels are for carbon monoxide; it may be before 70 PPM. It is for pregnant women, infants & children, the elderly and all people of vulnerable health. Bob Dwyer, CSME Carbon Monoxide Safety

Tribute
George Kerr, a pioneer in smoke and carbon monoxide alarm manufacturing passed away in his home during the early morning of July 4, 2017. George will always be remembered for his passion to save lives and protect the health of people through low level carbon monoxide detection and alarming. He lived for over 84 years, beginning his career in fire safety in 1953. “We’ll never know how many lives we’re saving, but I know we are saving a few.” George E. Kerr (1933-2017)

These following links may be of some use to you:
- The World Clock - Time Zones







- Carbon monoxide toxicity-Emergency Medicine Ireland
- Carbon Monoxide Survivor- Views from those who have been poisoned.
- Carbon Monoxide detection- National Fire Protection Association

· Please take CARBON MONOXIDE SAFETY CARE during all holiday and everyday activities.
___ 

U.S. Carbon Monoxide Laws for each state
National Conference of State Legislatures
As of March 2018, a majority of states have enacted statutes regarding carbon monoxide (CO) detectors, and another 11 have promulgated regulations on CO detectors. Alaska requires detectors approved by the state fire marshal be installed in all dwellings. Connecticut requires them in all new construction, as does New Hampshire, Oregon, Pennsylvania, Rhode Island, Utah, Vermont, Washington and West Virginia. Florida also requires them in new construction, and in every room with a boiler. Minnesota passed a law requiring detectors in motor boats.

CO Detectors in U.S. Homes
27 states and the District of Columbia require carbon monoxide detectors in private dwellings via state statute: Alaska, California, Colorado, Connecticut, District of Columbia, Florida, Georgia (via adoption of the International Residential Code), Illinois, Iowa, Maine, Maryland, Massachusetts, Michigan, Minnesota, Nebraska, New Hampshire, New Jersey, New York, North Carolina, Oregon, Pennsylvania, Rhode Island, Tennessee, Utah, Vermont, Washington, West Virginia and Wisconsin. Certain states limit the installation to buildings with fossil-fuel burning devices, others only require the device be installed upon the sale of the property or unit.

Another 11 states require carbon monoxide detectors in private dwellings regulatorily through the adoption of the International Residential Code or via an amendment to their state’s building code: Alabama, Georgia, Idaho, Kentucky, Louisiana, New Mexico, North Dakota, Oklahoma, South Carolina, Virginia, and Wyoming.

CO Detectors in U.S. Schools
California, Connecticut, Illinois, Maine and Maryland require carbon monoxide (CO) detectors in school buildings.

CO Detectors in U.S. Hotels and Motels
Fourteen states require the installation of carbon monoxide detectors in hotels and motels under the statute. - Three of those states (New Jersey, Vermont and Wisconsin) have complementary administrative regulations. - Two states (Kansas and Washington) have requirements through administrative regulations alone.
___

Ontario Canada Carbon Monoxide Alarm Legislation
Ministry of Community Safety & Correctional Services
Hawkins-Gignac Act
Fire Protection and Prevention Act, 1997
___ 

Red Cross - Disaster Relief to safely assist law enforcement, fire department, utility company, city, county and state authorities as repair and rebuilding moves forward. Bob Dwyer, CSME Carbon Monoxide Safety

Nationally, the Red Cross provides food and shelter to people affected by as many as 70,000 fires annually, or about one fire every eight minutes.

The following companies
are acknowledged for their continued support of carbon monoxide safety education and this daily news blog. They may just have what you are looking for.

The Energy Conservatory
Masimo - see RAD 57
Mahugh Fire & Safety
ESCO Institute
TPI - Test Products International
------------------------------------------------